HPLC Column, RP C8 Octyl, 5um, 2.1mm ID x 50mm Length, 100A. Cogent Brand. 1 EA.

Additional Information:

Cogent RP C8™ HPLC Columns are designed for reliable reversed-phase chromatography using a traditional octyl (C8) bonded stationary phase. Manufactured with ultra-high purity silica and fully double end capped bonding technology, these columns provide consistent retention, improved peak shape, and long service life. The RP C8™ phase is a USP L7 equivalent chemistry and is commonly used as an alternative for methods developed on comparable C8 columns. Compared to C18 phases, RP C8™ typically provides reduced retention while maintaining excellent selectivity for many hydrophobic and neutral compounds.

68508-05P-2 is packed with 5 µm RP C8™ particles featuring a 100 Å pore size in a 2.1 mm ID x 50 mm length format. This short, narrow-bore column is designed for rapid analyses while minimizing solvent consumption. The 5 µm particle size produces relatively low backpressure, making the column compatible with many HPLC and LC-MS systems. The RP C8™ stationary phase is particularly well suited for hydrophobic compounds, neutral analytes, and long-chain fatty acids where less retention than a C18 column is desired.

The 2.1 mm ID format is especially popular for LC-MS applications because reduced flow rates can improve mass spectrometer compatibility and reduce mobile phase consumption. Optimum performance typically occurs at approximately 0.2-0.3 mL/min. Standard HPLC systems used with this column must be capable of delivering reliable low flow rates with minimal pulsation, and detectors should utilize appropriately low-volume flow cells to minimize extra-column dispersion and preserve chromatographic efficiency.

Key Benefits

  • RP C8™ stationary phase

  • USP L7 equivalent chemistry

  • Octyl (C8) bonded phase

  • Fully double end capped

  • Ultra-high purity silica support

  • 100 Å pore size

  • Fast 50 mm column length

  • Reduced solvent consumption

  • Lower retention than C18 phases

  • Excellent for LC-MS applications

Typical Applications

  • Reversed-phase HPLC

  • LC-MS analysis

  • Method development

  • Method scouting

  • Long-chain fatty acid analysis

  • Hydrophobic compound separations

  • Neutral compound analysis

  • Pharmaceutical analysis

  • Environmental testing

  • High-throughput screening

Specifications

  • Product Type: HPLC Column

  • Stationary Phase: RP C8™

  • USP Classification: L7

  • Chromatography Mode: Reversed Phase

  • Bonded Phase: Octyl (C8)

  • Endcapping: Fully Double End Capped

  • Particle Size: 5 µm

  • Pore Size: 100 Å

  • Column Dimensions: 2.1 mm ID x 50 mm

  • Recommended Flow Rate: 0.2-0.3 mL/min

  • Column Hardware: Stainless Steel

  • Brand: Cogent

Important Notes

  • Designed for fast reversed-phase HPLC and LC-MS analyses

  • Provides lower retention than comparable C18 columns

  • Suitable for hydrophobic and moderately non-polar compounds

  • Excellent choice for long-chain fatty acid separations

  • Frequently used as a scouting column during method development

  • 50 mm length helps reduce analysis times and solvent consumption

  • 5 µm particles provide low backpressure and broad instrument compatibility

  • Requires an HPLC system capable of precise and reliable low flow rate delivery

  • Low-volume detector flow cells are recommended to maximize performance

  • Manufactured using ultra-high purity silica and fully double end capped bonding technology


 

© Copyright 2026. MICROSOLV. All Rights Reserved. Website & Hosting by BlueTone Media